Page 165 - journal-6-2-S-Full
P. 165
ÒˆÙ «“√ “√°“√·æ∑¬å·ºπ‰∑¬·≈–°“√·æ∑¬å∑“߇≈◊Õ° ªï∑’Ë ˆ©∫—∫∑’Ë Ú æƒ…¿“§¡- ‘ßÀ“§¡ (©∫—∫‡ √‘¡) ÚııÒ
°“√æ—≤π“«‘∏’«‘‡§√“–Àå ·≈–°“√»÷°…“§«“¡∂Ÿ°µâÕß·¡àπ¬”¢Õß«‘∏’«‘‡§√“–Àå “√
ÕÕ°ƒ∑∏‘Ï Madecassoside ·≈– Asiaticoside „π “√ °—¥∫—«∫°
Ò Ò Ú
ÿ«√√≥“ ‡À≈◊Õß™≈∏“√ , ™”π“≠ ¿—µ√æ“π‘™ , ª∞¡ ‚ ¡«ß»å
Ò
¿“§«‘™“‡¿ —™‡§¡’ §≥–‡¿ —™»“ µ√å ®ÿÓ≈ß°√≥å¡À“«‘∑¬“≈—¬
Ú
§≥–‡¿ —™»“ µ√å ¡À“«‘∑¬“≈—¬√—ß ‘µ
À≈—°°“√·≈–‡Àµÿº≈ “√ Madecassoside (MS) ·≈– Asiaticoside (AS) ‡ªìπ “√ÕÕ°ƒ∑∏‘Ï„π ¡ÿπ‰æ√∫—«∫° ´÷Ëߪ√‘¡“≥
“√¥—ß°≈à“«¡’§«“¡º—π·ª√µ“¡ “¬æ—π∏ÿå Õ“¬ÿ ƒ¥Ÿ°“≈ ·≈– ¿“æ·«¥≈âÕ¡„π°“√‡®√‘≠‡µ‘∫‚µ ‡¡◊ËÕπ” “√ °—¥∫—«∫°¡“
„™â‡ªìπ«—µ∂ÿ¥‘∫„π°“√‡µ√’¬¡¬“ ·≈–‡§√◊ËÕß ”Õ“ß ®÷ß¡—°¡’ªí≠À“„π¥â“π§«“¡ ¡Ë”‡ ¡Õ¢Õߪ√‘¡“≥ “√ÕÕ°ƒ∑∏‘Ï„π “√
°—¥·µà≈–√ÿàπ ¥—ßπ—Èπ ®÷߉¥â»÷°…“°“√«‘‡§√“–À凿◊ËÕ§«∫§ÿ¡§ÿ≥¿“æ¢Õß “√ MS·≈– AS „π “√ °—¥∫—«∫°
«—µ∂ÿª√– ß§å æ—≤π“«‘∏’«‘‡§√“–Àå·≈–»÷°…“§«“¡∂Ÿ°µâÕß·¡à𬔠(validation) ¢Õß«‘∏’«‘‡§√“–Àå MS ·≈– AS „π “√ °—¥
∫—«∫°
«‘∏’¥”‡π‘π°“√ Ò) æ—≤π“«‘∏’ TLC-Densiotometry „π°“√·¬°·≈–«‘‡§√“–ÀåÀ“ª√‘¡“≥ MS ·≈– AS „π “√ °—¥∫—«∫°
Ú) »÷°…“§«“¡∂Ÿ°µâÕß·¡àπ¬”¢Õß«‘∏’«‘‡§√“–Àå “√ °—¥∫—«∫° µ“¡¢âÕ°”Àπ¥¢Õß ICH
º≈°“√»÷°…“ Ò) ‰¥â«‘∏’«‘‡§√“–Àå MS·≈– AS „π “√ °—¥∫—«∫°¥â«¬«‘∏’ TLC-Densitometry ‚¥¬„™â·ºàπ Silica Gel GF
¢π“¥ Òxı ´¡., Developing solvent ‡ªìπ CHCl : MeOH : H O (Òı:˜:Ò), spray reagent ‡ªìπ .Ú% anthrone,
3 2
Densitometer scanner ∑’Ë ıÚı π“‚π‡¡µ√ æ∫«à“§à“ Rf ¢Õß MS ·≈– AS ¡’§à“ .ÚÙ ·≈– .Ú˘ µ“¡≈”¥—∫ ·≈–§à“
absorption peak ∑’Ë ÒÛÒ ·≈– ÒÙÒ ¡¡. µ“¡≈”¥—∫ ‚¥¬‰¡à¡’ “√Õ◊Ëπ Ê √∫°«π Ú) º≈°“√»÷°…“§«“¡∂Ÿ°µâÕß·¡àπ¬”
¢Õß«‘∏’«‘‡§√“–Àåª√‘¡“≥ “√ MS ·≈– AS „π “√ °—¥∫—«∫°¥â«¬«‘∏’ TLC-Densitometry æ∫«à“ «‘∏’¥—ß°≈à“«‡¢â“‡°≥±å
µ“¡¢âÕ°”Àπ¥ ICH ‚¥¬¡’√“¬≈–‡Õ’¬¥¥—ßπ’È Ú.Ò) ¡’ specificity ¥’ ‰¡à¡’ “√„¥ Ê √∫°«π, Ú.Ú) ¡’ percentage recovery
¢Õß “√ MS = ˘˘.¯Ò ± Ò.ı ·≈–¢Õß “√ AS = ˘˘.Ò¯ ± Ò.˘˘, Ú.Û) ¡’ repeatability ¥’ ‚¥¬¡’§à“ %RSD ¢Õß “√
2
MS = Ò.˜ ·≈–¢Õß “√ AS = Ò.Ò¯, Ú.Ù) ¡’§à“ linearity R > .˘˘, Ú.ı) ¡’ range (¡§°.) ¢Õß “√ MS Õ¬Ÿà„π
™à«ß Ò.¯-ÚÒ.ˆ ·≈–¢Õß “√ AS Õ¬Ÿà„π™à«ß .˜¯-Òı.ˆ, Ú.ˆ) ¡’ lower limit of detection (LLOD)(¡§°.)
¢Õß “√ MS = .ÙÛÙ ·≈–¢Õß “√ AS = .ÛÒ, Ú.˜) ¡’§à“ lower limit of quantitation (LLOQ)(¡§°.) ¢Õß “√
MS = Ò.ÛÒÙ ·≈–¢Õß “√ AS = .˘ÒÛ
¢âÕ √ÿª «‘∏’«‘‡§√“–Àå TLC-Densitometry ∑’Ëæ—≤π“¢÷Èππ’È ¡’§«“¡∂Ÿ°µâÕß·¡à𬔠Ÿß ‡™◊ËÕ∂◊Õ‰¥â ‡ªìπ«‘∏’∑’Ëßà“¬ –¥«° √«¥‡√Á«
ª√–À¬—¥ ‡À¡“–∑’Ë®–„™â§«∫§ÿ¡§ÿ≥¿“æ “√ °—¥∫—«∫°